Feline distemper, also known as feline panleukopenia and feline infectious enteritis, is an acute, highly contagious disease of cats. Clinical manifestations are characterized by sudden onset of high fever, intractable vomiting, diarrhea, dehydration, circulatory disturbances, and a dramatic decrease in white blood cells.
The virus can infect not only domestic cats but also other felines. Cats of all ages can be infected. In most cases, cats under 1 year of age are susceptible, with an infection rate of up to 70% and a mortality rate of 50%-60%, and a maximum mortality rate of 80%-90% in kittens under 5 months of age. This kit is used to detect feline microvirus antigens in feces and vomit of cats.
The Feline Panleukopenia Virus Antigen Test Kit uses a rapid immunochromatographic detection technique for the detection of feline fever virus antigen. A sample obtained from cat feces and vomit is added to the spiked wells and moved along the chromatographic membrane together with a colloidal gold-labeled anti-FPV monoclonal antibody. If the FPV antigen is present in the sample, it binds to the antibody on the detection line (T) and shows a burgundy color. If FPV antigen is not present in the sample, no color reaction is produced.
The Feline Panleukopenia Virus Antigen Test Kit is able to detect Feline Panleukopenia Virus Antigen concentration, demonstrating quantitative results. The test serves only as an aid to the diagnosis. For professional use only.
For rapid screening of Feline Panleukopenia Virus in feces and vomit of cats. (FPV).
Note: The above reading time is conducted at a room temperature of 15-30℃. If the temperature is lower than 15℃, the reading time should be extended. If the temperature is higher than 30℃, the reading time should be shortened.
Negative: In the test window, only one fuchsia-colored line appears next to “C”.
Positive: In the test window, two distinct colored lines appear simultaneously next to “T” & “C”.
Invalid: no color line visible next to “C”.
NOTE: Invalid test results can be caused by various reasons and should be re-tested.
Cat.No | CY-G004-1 | CY-G004-10 | CY-G004-25 |
Component | 1 Test/Box | 10 Tests/Box | 25 Tests/Box |
Test device in foil bag (including Test card, pipette & desiccant) | 1 pc | 10 pcs | 25 pcs |
Sample dilution vial (contains extraction buffer) | 1 vials | 10 vials | 25 vials |
Sampling swab | 1 pc | 10 pcs | 25 pcs |
IFU | 1 pc | 1 pc | 1 pc |