Feline culexvirus (FCV) belongs taxonomically to the family Culexidae and genus Culex. The virus multiplies in the brain plasma, sometimes in a crystalline or bead-like arrangement. The virus is resistant to lipid solvents (ether, chloroform and deoxycholines); inactive at pH 3, stable at pH 4-5; inactivated at 50 degrees C for 30 minutes. The main manifestations are upper respiratory signs, i.e. mental depression, plasma and mucous rhinorrhea, conjunctivitis, stomatitis, tracheitis, and bronchitis with biphasic fever. Feline cupulovirus infection is a frequent disease in cats with high morbidity and low mortality. This feline calicivirus antigen test kit is used to detect feline culexvirus antigen in feline ocular, nasal and oral secretions.
Rapid immunochromatographic assay technique for detection of feline culexvirus antigen. A sample obtained from the cat’s ocular, nasal and oral secretions is added to the spiked wells and moved along the chromatographic membrane together with a colloidal gold-labeled anti-FCV monoclonal antibody. If the FCV antigen is present in the sample, it binds to the antibody on the detection line (T) and shows a burgundy color. If FCV antigen is not present in the sample, no color reaction is produced.
The Feline Calicivirus Antigen Test Kit is able to detect Feline Calicivirus Antigen concentration, demonstrating quantitative results. The test serves only as an aid to the diagnosis. For professional use only.
For rapid screening of Feline Calicivirus in ocular, nasal and oral secretions of cats. (FCV).
Note: The above reading time is conducted at a room temperature of 15-30℃. If the temperature is lower than 15℃, the reading time should be extended. If the temperature is higher than 30℃, the reading time should be shortened.
Negative: In the test window, only one fuchsia-colored line appears next to “C”.
Positive: In the test window, two distinct colored lines appear simultaneously next to “T” & “C”.
Invalid: no color line visible next to “C”.
NOTE: Invalid test results can be caused by various reasons and should be re-tested.
Cat.No | CY-G002-1 | CY-G002-10 | CY-G002-25 |
Component | 1 Test/Box | 10 Tests/Box | 25 Tests/Box |
Test device in foil bag (including Test card, pipette & desiccant) | 1 pc | 10 pcs | 25 pcs |
Sample dilution vial (contains extraction buffer) | 1 vials | 10 vials | 25 vials |
Sampling swab | 1 pc | 10 pcs | 25 pcs |
IFU | 1 pc | 1 pc | 1 pc |